{"title":"KEES VAN DER WESTEN","description":"","products":[{"product_id":"kees-van-der-westen-speedster","title":"KEES VAN DER WESTEN  SPEEDSTER","description":"\u003cdiv data-renderer=\"lm\"\u003e\n\u003ch3 class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eKEES VAN DER WESTEN SPEEDSTER\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe Kees van der Westen Speedster is a masterpiece of espresso engineering, combining industrial-grade precision with breathtaking aesthetics. Designed as the ultimate single-group espresso machine, it offers extreme stability, superior control, and a speedy workflow for the most demanding specialty coffee environments.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"core-technology\"\u003eCore Technology\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eDual Boiler System\u003c\/strong\u003e: Two high-grade 316L stainless steel boilers operating independently a 3.5-liter steam boiler (1,800W) and a 2.1-liter coffee boiler (900W). Each is managed by a precise electronic temperature controller (PID) to ensure thermal consistency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSaturated Group Head\u003c\/strong\u003e: The coffee boiler and group are integrated into one large, thermally stable unit. Water is pre-heated in a heat-exchanger cross-flow system before entering the coffee boiler, ensuring near-brew temperature upon arrival.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePrecise Pre-Infusion\u003c\/strong\u003e: Features a two-phase stepless progressive pre-infusion cylinder. The lever allows for manual infusion using mains pressure, followed by a gradual pressure build-up preventing channeling and maximizing flavor yield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThermal Stability\u003c\/strong\u003e: A natural thermo-syphon flow circulates water through the group head to a \"thermal sweet spot,\" maintaining absolute temperature consistency from the boiler to the puck.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"advanced-features--intuitive-control\"\u003eAdvanced Features \u0026amp; Intuitive Control\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCustomizable Hot Water\u003c\/strong\u003e: A dual-function toggle switch allows for two distinct hot water temperatures boiling hot or a pre-mixed, adjustable temperature stream.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIntuitive Ergonomics\u003c\/strong\u003e: Featuring a high-visibility shot timer, pressure gauge (measuring actual puck pressure), and a gear lever for manual control. The height-adjustable drip tray adapts to any cup size.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety \u0026amp; Reliability\u003c\/strong\u003e: Multi-probe monitoring ensures boilers are safely filled before heating elements activate. Integrated overheat cut-outs, safety valves, and an expansion valve provide comprehensive protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIndustrial Design\u003c\/strong\u003e: Built using high-grade 316L stainless steel with meticulous welding (internal and external) to eliminate crevices and corrosion risk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCoffee Boiler\u003c\/strong\u003e: 2.1 Liters (316L Stainless Steel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSteam Boiler\u003c\/strong\u003e: 3.5 Liters (316L Stainless Steel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePower Settings\u003c\/strong\u003e: Normal (3,100 W) or Reduced (2,200 W)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCurrent (230V)\u003c\/strong\u003e: 13.5 A (Normal) or 9.6 A (Reduced)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePump\/Motor\u003c\/strong\u003e: External rotary pump with 300W motor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTension\u003c\/strong\u003e: 220–240 V | 50–60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: ~45 kg (approx. 99 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"KEES VAN DER WESTEN","offers":[{"title":"Default Title","offer_id":45077558526152,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/6504\/1608\/files\/speedster_4830-Photoroom.png?v=1778061234"},{"product_id":"kees-van-der-westen-spiritello","title":"KEES VAN DER WESTEN - SPIRITELLO","description":"\u003cdiv data-renderer=\"lm\"\u003e\n\u003ch3 class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eKEES VAN DER WESTEN SPIRITELLO\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe Kees van der Westen (KvdW) Spiritello is a sophisticated dual-boiler lever espresso machine that blends the tactile, artisan experience of a traditional spring-lever group with the modern precision of PID-controlled stainless steel technology. Designed for those who demand uncompromising build quality and temperature stability, the Spiritello is a masterclass in hydraulic engineering and professional performance.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"key-technical-specifications\"\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCoffee Boiler\u003c\/strong\u003e: 0.8 L (316L Stainless Steel) with 450W PID-controlled element.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSteam Boiler\u003c\/strong\u003e: 3.5 L (316L Stainless Steel) with dual 900W heating spirals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eWater Tank\u003c\/strong\u003e: 3.5 L integrated reservoir (316L Stainless Steel).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePump \u0026amp; Motor\u003c\/strong\u003e: Internal stainless steel rotary pump (180W), rated for continuous use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul class=\"marker:text-quiet list-disc\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eNormal Setting\u003c\/strong\u003e: Up to 2,720 W (at 240V).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eReduced Setting\u003c\/strong\u003e: Down to 2,050 W (at 230V).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTension\u003c\/strong\u003e: 220–240 V | 50–60 Hz (1-phase).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"core-technology\"\u003eCore Technology\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eDual Boiler System\u003c\/strong\u003e: Independent 316L stainless steel boilers provide superior resistance to aggressive water and long-term durability. Each boiler can be toggled on\/off individually, and both are easily drained via dedicated ball valves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSaturated Group Design\u003c\/strong\u003e: The group and coffee boiler are integrated into a single, massive 0.8L unit. Cold water is pre-heated through a steam boiler heat-exchanger, ensuring precise, near-brew-temperature water enters the coffee boiler.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eLever Group Dynamics\u003c\/strong\u003e: The spring-lever system features a PEEK-piston a heat-neutral material that prevents temperature loss and residue buildup. Users can control pre-infusion pressure (1.5–4 bar) via an adjustable knob, while the pump handles saturation and initial extraction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSilent Operation\u003c\/strong\u003e: If the water mains pressure is 3 bar or higher, the pump can be disengaged, allowing for a completely silent brewing experience powered by the lever’s spring mechanism.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"temperature--flow-stability\"\u003eTemperature \u0026amp; Flow Stability\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThermal Efficiency\u003c\/strong\u003e: By utilizing 316L stainless steel instead of traditional brass, the machine reduces heat transfer to the surrounding environment by nearly tenfold, ensuring heat stays exactly where it’s needed: at the coffee puck.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eAdvanced Steaming\u003c\/strong\u003e: The large 3.5L steam boiler, controlled by PID, delivers powerful, long-lasting steam. The double-walled stainless steel wand, finished with a PEEK tip, prevents milk from burning or sticking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHot Water Precision\u003c\/strong\u003e: Features a mix-manifold that combines boiling water from the boiler with cold water to provide a steady, non-spattering flow. Both the temperature (via an adjustable restrictor) and the dispensing quantity (via digital display) are fully customizable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"build--safety\"\u003eBuild \u0026amp; Safety\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: All internal components and welds are finished to eliminate crevices, significantly reducing the risk of corrosion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHydraulic Flow\u003c\/strong\u003e: An automatic air-bleed system ensures trapped air is expelled during group activation, maintaining a consistent column of water for reliable extraction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIntuitive Interface\u003c\/strong\u003e: Features a digital display for adjusting flushing quantities, steam\/water settings, and Eco-mode functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"KEES VAN DER WESTEN","offers":[{"title":"Default Title","offer_id":45077560426696,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/6504\/1608\/files\/spiritello-features-machine-Photoroom.png?v=1778061524"},{"product_id":"kees-van-der-westen-mirage-duette-triplette","title":"KEES VAN DER WESTEN MIRAGE (DUETTE \u0026 TRIPLETTE)","description":"\u003cdiv data-renderer=\"lm\"\u003e\n\u003ch3 class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eKEES VAN DER WESTEN MIRAGE (DUETTE \u0026amp; TRIPLETTE)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe Kees van der Westen (KvdW) Mirage is an icon of professional espresso engineering. Utilizing a highly efficient thermo-syphon heat-exchanger (HX) system, it is designed for high-volume environments that demand consistent thermal mass, legendary durability, and the unmistakable aesthetic of Dutch design.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"thermal-engineering--brewing\"\u003eThermal Engineering \u0026amp; Brewing\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThermo-Syphon System\u003c\/strong\u003e: A large copper steam boiler (13L for Duette, 19L for Triplette) acts as the primary heat source. Heat exchangers (450cc per group) run through this boiler to flash-heat water, while a continuous thermo-syphon loop circulates water between the HX and the group head.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThermal Mass Stability\u003c\/strong\u003e: Each group features a 4 kg solid brass head, providing immense thermal inertia to ensure the water temperature remains stable even during the most demanding service shifts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePrecise Restrictors\u003c\/strong\u003e: Water temperature is managed via internal restrictors (standard 1.5mm). By controlling the flow rate within the thermo-syphon loop, baristas can fine-tune group temperatures for different roast profiles (e.g., lower temps for dark roasts, higher for light roasts) without altering the main boiler pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eCrossflow Cooling\u003c\/strong\u003e: The Mirage utilizes a sophisticated crossflow system where incoming cold water is pre-warmed by the outgoing hot water, ensuring efficient temperature regulation before the water reaches the brew head.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"group relative my-[1em]\"\u003e\n\u003cdiv class=\"sticky top-0 z-10 h-0\" aria-hidden=\"true\"\u003e\n\u003cdiv class=\"w-full overflow-hidden bg-raised border-x md:max-w-[90vw] border-subtlest ring-subtlest divide-subtlest\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"w-full overflow-auto scrollbar-subtle rounded-lg border md:max-w-[90vw] border-subtlest ring-subtlest divide-subtlest bg-raised\"\u003e\n\u003ctable class=\"[\u0026amp;_tr:last-child_td]:border-b-0 my-0 w-full table-auto border-separate border-spacing-0 text-sm font-sans rounded-lg [\u0026amp;_tr:last-child_td:first-child]:rounded-bl-lg [\u0026amp;_tr:last-child_td:last-child]:rounded-br-lg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eSteam Boiler\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eHeating Power\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003ePhase Options\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eMirage Duette\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e13 Liters\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e3,200W (Normal) \/ 4,800W (High)\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e1-Phase or 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eMirage Triplette\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e19 Liters\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e6,000W\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTension\/Frequency\u003c\/strong\u003e: 220–240 V | 50–60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eOperating Pressure\u003c\/strong\u003e: 9 bar extraction (pump-assisted).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e: Integrated expansion valves (11–12 bar) and solenoid backup (15 bar).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"operational-philosophy\"\u003eOperational Philosophy\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003e\"Set it and forget it\" Stability\u003c\/strong\u003e: Once the restrictors are set to your preference, the Mirage is built to pull dozens of shots back-to-back. The system recovers rapidly because it does not rely on electrical resistance heating at the group, but rather the constant, massive thermal reservoir of the main boiler.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eThe Workflow\u003c\/strong\u003e: The Mirage is designed for professional use. KvdW recommends a brief 30–45cc flush before pulling a shot to ensure the water in the group neck is at the perfect temperature. Because of the large thermal mass of the brass group, users should avoid long flushes, which can prematurely cool the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIndustrial Longevity\u003c\/strong\u003e: Constructed with high-grade copper and brass, and featuring high-pressure rated solenoid valves, the Mirage is built to withstand the rigors of the busiest coffee bars in the world.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"KEES VAN DER WESTEN","offers":[{"title":"Default Title","offer_id":45077565276360,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/6504\/1608\/files\/mirage-table-1-2048x1366-Photoroom.png?v=1778062043"},{"product_id":"kees-van-der-westen-slim-jim-duette-amp-triplette","title":"KEES VAN DER WESTEN SLIM JIM (DUETTE \u0026 TRIPLETTE)","description":"\u003cdiv data-renderer=\"lm\"\u003e\n\u003ch3 class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eKEES VAN DER WESTEN SLIM JIM (DUETTE \u0026amp; TRIPLETTE)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe Slim Jim represents the pinnacle of Kees van der Westen’s (KvdW) technical evolution, designed specifically for high-volume specialty coffee shops that require a \"slim\" aesthetic without sacrificing the massive thermal power of a multi-boiler system. It is a masterpiece of stainless steel engineering, delivering uncompromising temperature stability and sophisticated pressure control in an elegant, modern form factor.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"core-technology\"\u003eCore Technology\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eMultiple Boiler System\u003c\/strong\u003e: The Slim Jim features independent boilers for every brew group and one massive steam boiler. All boilers are constructed from 316L stainless steel, chosen for its superior resistance to water-borne corrosion and long-term durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSaturated Group Design\u003c\/strong\u003e: The group head is welded directly to the 0.8L coffee boiler, forming a single, thermally massive unit. This setup ensures that water temperature at the puck is effectively identical to the PID-controlled temperature of the boiler, virtually eliminating heat loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eIntelligent Thermo-Syphon\u003c\/strong\u003e: Cold water is pre-heated through an internal heat exchanger in the steam boiler before entering the coffee boiler. An electronic sensor monitors the distribution block temperature, injecting cold water via a mixing chamber if the water is too hot, ensuring precise extraction temperatures even during peak rush hours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"professional-steam--dispensing\"\u003eProfessional Steam \u0026amp; Dispensing\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eHigh-Volume Steam\u003c\/strong\u003e: The insulated 10.5L steam boiler is the powerhouse of the machine, utilizing three heating spirals managed by solid-state relays to provide immense, dry, and consistent steam power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eVersatile Hot Water\u003c\/strong\u003e: The Slim Jim offers two dispensing modes: a user-adjustable \"mixed\" water flow (60–100°C) perfect for Americanos or tea, and a direct-from-boiler toggle for boiling water, ideal for black tea.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eAdvanced Steaming Options\u003c\/strong\u003e: Standard turning knobs are easily upgraded to toggle levers or unique foot-activated air-bulb switches, allowing baristas to achieve perfect microfoam while keeping their hands free for other tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"precision-extraction-pre-infusion\"\u003ePrecision Extraction (Pre-Infusion)\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSpring-Loaded Pre-Infusion\u003c\/strong\u003e: As the brew process begins, the group solenoid and pump activate, directing water into both the coffee bed and a dedicated pre-infusion cylinder.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eGradual Pressure Build\u003c\/strong\u003e: The piston inside the pre-infusion cylinder is restrained by a double-spring mechanism. Pressure rises gradually to ~4.5 bar, effectively swelling the coffee bed and sealing it against channeling before ramping up to the full extraction pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eLive Feedback\u003c\/strong\u003e: The pressure gauge is connected directly to the pre-infusion cylinder, giving the barista a real-time view of the actual extraction pressure at the puck not just the pump’s output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"technical-specifications-duette--triplette\"\u003eTechnical Specifications (Duette \u0026amp; Triplette)\u003c\/h2\u003e\n\u003cdiv class=\"group relative my-[1em]\"\u003e\n\u003cdiv class=\"sticky top-0 z-10 h-0\" aria-hidden=\"true\"\u003e\n\u003cdiv class=\"w-full overflow-hidden bg-raised border-x md:max-w-[90vw] dark:shadow-lg border-subtlest ring-subtlest divide-subtlest\"\u003e\n\u003ctable class=\"[\u0026amp;_tr:last-child_td]:border-b-0 my-0 w-full table-auto border-separate border-spacing-0 text-sm font-sans rounded-lg [\u0026amp;_tr:last-child_td:first-child]:rounded-bl-lg [\u0026amp;_tr:last-child_td:last-child]:rounded-br-lg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eFeature\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eDuette (2-Group)\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eTriplette (3-Group)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"w-full overflow-auto scrollbar-subtle rounded-lg border md:max-w-[90vw] border-subtlest ring-subtlest divide-subtlest bg-raised\"\u003e\n\u003ctable class=\"[\u0026amp;_tr:last-child_td]:border-b-0 my-0 w-full table-auto border-separate border-spacing-0 text-sm font-sans rounded-lg [\u0026amp;_tr:last-child_td:first-child]:rounded-bl-lg [\u0026amp;_tr:last-child_td:last-child]:rounded-br-lg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eFeature\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eDuette (2-Group)\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eTriplette (3-Group)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eCoffee Boiler\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e0.8 L (316L Stainless)\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e0.8 L per group (316L Stainless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eSteam Boiler\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e10.5 L (316L Stainless)\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e10.5 L (316L Stainless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eHeating Power (Steam)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e4,800W \/ 6,000W\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e4,800W \/ 6,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eHeating Power (Coffee)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e2 x 450W\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e3 x 450W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003ePeak Power (No Pump)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e6,325W - 7,975W\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e6,775W - 7,975W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sticky z-10 h-0\"\u003e\n\u003cdiv class=\"bg-base border-subtlest shadow-subtle pointer-coarse:opacity-100 keyboard:opacity-100 right-xs absolute bottom-xs flex rounded-md border opacity-0 transition-opacity group-hover:opacity-100 [\u0026amp;\u0026gt;*:not(:first-child)]:border-subtlest [\u0026amp;\u0026gt;*:not(:first-child)]:border-l\"\u003e\n\u003cdiv class=\"flex transition-opacity duration-300 [\u0026amp;_button]:hover:bg-transparent\"\u003e\n\u003cdiv class=\"relative flex items-center justify-center\"\u003e\n\u003cdiv class=\"inline-flex\"\u003e\u003csvg role=\"img\" class=\"inline-flex fill-current shrink-0\" width=\"16\" height=\"16\" stroke-width=\"1.75\"\u003e\u003cuse\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"flex transition-opacity duration-300 [\u0026amp;_button]:hover:bg-transparent\"\u003e\n\u003cdiv class=\"relative flex items-center justify-center\"\u003e\n\u003cdiv class=\"inline-flex\"\u003e\u003csvg role=\"img\" class=\"inline-flex fill-current shrink-0\" width=\"16\" height=\"16\" stroke-width=\"1.75\"\u003e\u003cuse\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eTension\u003c\/strong\u003e: 220–240 V | 50–60 Hz | 1-Phase or 3-Phase configurations available.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety Features\u003c\/strong\u003e: Redundant probe systems prevent dry-heating, while electronic cut-outs and safety valves protect the coffee and steam systems from over-pressure or overheating.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003c\/div\u003e","brand":"KEES VAN DER WESTEN","offers":[{"title":"Default Title","offer_id":45077567013064,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/6504\/1608\/files\/kvdw-slim-jim-hotspots-1_1_-Photoroom.png?v=1778062475"},{"product_id":"kees-van-der-westen-slim-jim-idrocompresso","title":"KEES VAN DER WESTEN SLIM JIM IDROCOMPRESSO","description":"\u003cdiv data-renderer=\"lm\"\u003e\n\u003cdiv data-renderer=\"lm\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eKEES VAN DER WESTEN SLIM JIM IDROCOMPRESSO\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe Slim Jim Idrocompresso by Kees van der Westen (KvdW) is a pinnacle of espresso engineering, melding the tactile, artisan soul of spring-lever extraction with the industrial stability of 316L stainless steel multi-boiler technology. It is a machine built for the specialty barista who values the classic \"theatrical\" lever workflow but requires the uncompromising thermal accuracy of a modern PID-controlled system.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"technical-specification-overview\"\u003eTechnical Specification Overview\u003c\/h2\u003e\n\u003cdiv class=\"group relative my-[1em]\"\u003e\n\u003cdiv class=\"sticky top-0 z-10 h-0\" aria-hidden=\"true\"\u003e\n\u003cdiv class=\"w-full overflow-hidden bg-raised border-x md:max-w-[90vw] border-subtlest ring-subtlest divide-subtlest\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"w-full overflow-auto scrollbar-subtle rounded-lg border md:max-w-[90vw] border-subtlest ring-subtlest divide-subtlest bg-raised\"\u003e\n\u003ctable class=\"[\u0026amp;_tr:last-child_td]:border-b-0 my-0 w-full table-auto border-separate border-spacing-0 text-sm font-sans rounded-lg [\u0026amp;_tr:last-child_td:first-child]:rounded-bl-lg [\u0026amp;_tr:last-child_td:last-child]:rounded-br-lg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eFeature\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eSlim Jim Duette Idrocompresso\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eSlim Jim Triplette Idrocompresso\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eCoffee Boilers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e2 × 0.8L (316L Stainless)\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e3 × 0.8L (316L Stainless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eSteam Boiler\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e10.5L (316L Stainless)\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e10.5L (316L Stainless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eHeating Power (Steam)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e4,800W \/ 6,000W\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e4,800W \/ 6,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eHeating Power (Coffee)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e2 × 450W\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e3 × 450W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003ePeak Power (Normal\/High)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e~6,180W \/ 7,380W\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e~6,630W \/ 7,830W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003ePhases Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e1-Phase or 3-Phase\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e1-Phase or 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003cstrong\u003eVoltage\/Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e220–240 V\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-base first:mt-0\" id=\"key-performance-benefits\"\u003eKey Performance Benefits\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eLever Group Evolution\u003c\/strong\u003e: The Idrocompresso re-engineers the classic spring-lever. By moving the lever position away from the barista and incorporating a safe, thumb-operated locking mechanism, KvdW has eliminated the danger of accidental \"kicks\" while providing the consistent, decaying-pressure profile that lever machines are famous for.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePEEK Piston Technology\u003c\/strong\u003e: The lower part of the piston is crafted from PEEK, a heat-neutral polymer. This ensures the piston does not absorb heat from the brew water, keeping the thermal system perfectly stable even during high-volume sessions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003ePrecision PID Control\u003c\/strong\u003e: Each group is thermally independent and monitored by a PID system that \"learns\" the heating cycle, allowing for ±0.1°C temperature adjustments via the digital interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eSafety-First Hydraulic Logic\u003c\/strong\u003e: The brain of the machine prevents heating until both the steam and coffee boilers are confirmed full, protecting the heating elements from dry-firing. If a group solenoid is triggered for over 3 minutes, the machine automatically shuts off the group to prevent damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003cstrong\u003eVisual Diagnostics\u003c\/strong\u003e: Every group features a shot timer and a pressure gauge, while individual control lights at the base of the machine provide instant visual confirmation that each heating spiral is functioning correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"KEES VAN DER WESTEN","offers":[{"title":"Default Title","offer_id":45077569798344,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0268\/6504\/1608\/files\/feature-3-boiler-Photoroom.png?v=1778062884"}],"url":"https:\/\/www.benkibrewingtools.com\/collections\/kees-van-der-westen.oembed","provider":"Benki Brewing Tools","version":"1.0","type":"link"}